Edelbrock Automobile Parts 10220275 User Manual

Edelbrock Vortec EGR Adapter Kit  
Catalog #2899  
INSTALLATION INSTRUCTIONS  
PLEASEstudy these instructions carefully before installing your EGR Adapter kit. If you have any questions or problems, contact our Technical Hotline  
at: 1-800-416-8628 , 7am - 5pm, Monday-Friday, Pacific Standard Time or e-mail us at edelbrock@edelbrock.com.  
DESCRIPTION: This adapter kit is intended for the customer who already has a set of headers in his truck that he wishes to re-use with his new Vortec  
engine.  
KIT CONTENTS  
PARTS REQUIRED  
Qty.  
1
Description  
Qty.  
1
Description  
Vortec EGR Supply Fitting (#24-9715)  
GM #10220275 EGR Supply Tube  
GM #12552329 Adapter Fitting  
1
.75” O.D. x 1.25” Long, Bent Tube (#79-9643)  
.75” O.D. x 6” Long, Bent Tube (#79-9574)  
1
1
Edelbrock Kit #2899  
GM EGR Supply Tube #10220275  
INSTALLATION INSTRUCTIONS  
GM Adapter Fitting #12552329  
1. Attach GM EGR Supply Tube (#10220275) and GM Adapter Fitting (#12552329) to intake manifold (See Fig. 1). Do not tighten at this time!  
2. Attach supplied EGR Supply Fitting to the GM Adapter Fitting (See Fig. 1). Do not tighten.  
3. Using one of the Edelbrock bent tubes at a time, position the tubes agains the under side of the fitting and against the side of the header primary  
tube. (Use the tube that allows the EGR-supply tube to be positioned in the vehicle so it has adequate clearance around other components). Bent  
tubes can be trimmed as needed (See Fig. 1).  
4. Once you have selected the tube that fits your application best, remove the Edelbrock  
fitting from the EGR-supply tube and weld the fitting to the selected bent tube.  
5. Re-install the fitting with the welded on tube and position the tube opening against the  
header primary tube, mark the primary tube, remove the header and drill a 1/2” diameter  
hole where you have marked.  
6. For best fit, re-install the header into position, re-install the fitting onto the EGR-supplied  
tube and tack weld.  
7. Remove the header and complete the weld.  
8. Re-install header with new gaskets and hardware. Tighten the GM adapter fitting into the  
welded on tube and fitting, and tighten the fittings on both ends of EGR-supply tube.  
Figure 1 - Installed Supply Tube  
WARNING!!!  
Exhaust gas contains carbon monoxide, a deadly invisible gas. Correct any leaks before driving!  
Edelbrock Corporation • 2700 California Street • Torrance, CA 90503  
Toll-Free Tech Line: 1-800-416-8628  
Tech E-Mail: edelbrock@edelbrock.com  
©2004 Edelbrock Corporation  
Rev. 12/04  
Catalog #2899  
Brochure #63-0234  
 

ConnectPRO Computer Monitor SL 01 User Manual
Craftsman Snow Blower C950 52474 7 User Manual
Craftsman Trimmer 24074805 User Manual
Creative Computer Drive RFC 2364 User Manual
Creda Cooktop S930E User Manual
Dixon Lawn Mower 13633 0702 User Manual
Electro Voice Portable Speaker EVX 184 User Manual
Estate Range W10203464A User Manual
Euro Pro Electric Steamer KS315W User Manual
GE Washer G153 User Manual